INTRODUCTION

KinePak is a 2 part explosive that is not explosive until mixed. The two components can be transported and stored under the “Limited Quantity” designation – the components do not require magazine storage. When mixed, KinePak can be initiated with a Number 8* Detonator or 10 gram per metre Detonating Cord. The KinePak containers incorporate a recess for the Detonator or Detonating Cord. KinePak has been used for over 30 years in the United States.

PROPERTIES

When mixed, KinePak has a density of 1.20 grams / cubic centimeter, velocity of detonation (VOD) of 6,300 metres / second (20,700 feet per second) and a detonation pressure of 121 kiloBars.

APPLICATIONS

KinePak can be used for any application where a Detonator / Detonating Cord sensitive blasting explosive is required. KinePak can be used as a Booster, in agricultural blasting, demolition, explosive ordnance disposal (EOD) and oilfield abandonment. KinePak does come in rigid bottles so the correct sized hole will be required for some applications. KinePak can be used in plastic bags or as the “pouch” product for other geometries.

Attach the arming needle to the Liquid Tube Insert the arming needle into the Solid Component and dispense Liquid. Attach the Detonator or Detonating Cord.

SIZES AND PACKAGING

DESIGNATION DESCRIPTION DIMENSIONS
(MILLIMETRES)
APPROXIMATE
N.E.Q. (GRAMS)
UNITS
PER CASE
KINEPAK 1/3 S Third Stick - Plastic Tube 32 Dia x 180 Long 150 96
KINEPAK 1/2 S Half Stick - Plastic Tube 35 Dia x 205 Long 230 75
KINEPAK 1 S Full Stick - Plastic Tube 51 Dia x 230 Long 455 48
KINEPAK 1 BB Boulder Buster Bottle 64 Dia x 130 Long 455 50
KINEPAK 1 P Foil Pouch 38 Thk x 114 x 130 455 48

Download this brochure in Adobe Reader format (108 KB pdf)

CURRENT AUTHORISATIONS

KinePak is currently authorized for use in New South Wales, South Australia and Queensland.